异常重启记录
[193526] ===============display version===============
[193526]H3C Comware Software, Version 7.1.070, Release 7754P10
[193526]Copyright (c) 2004-2023 New H3C Technologies Co., Ltd. All rights reserved.
[193526]H3C S7506X-G uptime is 127 weeks, 6 days, 1 hour, 23 minutes
[193526]Last reboot reason : IRF Merge reboot
547] MemberID NewID IRF-Port1 IRF-Port2
[193547] 1 1 Ten-GigabitEthernet1/0/0/39 disable
[193547] Ten-GigabitEthernet1/0/0/40
[193547] 2 2 disable Ten-GigabitEthernet2/0/0/39
[193547] Ten-GigabitEthernet2/0/0/40
[193547]=========================================================
存在镜像配置:
[103400][GH-HJ-7506X-G-IRF]dis mirroring-group all
[103400]Mirroring group 1:
[103400] Type: Local
[103400] Status: Incomplete
[103400] Mirroring port:
[103400] GigabitEthernet1/0/0/1 Both
[103400] GigabitEthernet1/0/0/2 Both
[103400] GigabitEthernet1/0/0/3 Both
[103400] GigabitEthernet1/0/0/4 Both
[103401]Mirroring group 2:
[103401] Type: Local
[103401] Status: Active
[103401] Mirroring port:
[103401] GigabitEthernet2/0/0/1 Both
[103401] GigabitEthernet2/0/0/2 Both
[103401] GigabitEthernet2/0/0/3 Both
[103401] GigabitEthernet2/0/0/4 Both
当前版本存在已知问题如下:
· 问题现象:设备配置端口镜像后出现单板重启情况。
· 问题产生条件:镜像源端口在 SD或SC系列接口板上,且单板上镜像流量总带宽大于镜像目的口带宽。
· 说明:无。
升级到R7764版本解决
该案例暂时没有网友评论
✖
案例意见反馈
亲~登录后才可以操作哦!
确定你的邮箱还未认证,请认证邮箱或绑定手机后进行当前操作