S7506X-G端口震荡影响业务

  • 0关注
  • 0收藏 10浏览
粉丝:0人 关注:0人

问题描述

某局点S7506X-G的g2/1/0/6接口与g1/1/0/5接口在短时间内反复UP/DOWN,导致客户摄像头业务受到影响:

行 5861: %@225215%Sep  6 02:00:50:959 2026 CORE-Video IFNET/3/PHY_UPDOWN: Physical state on the interface GigabitEthernet2/1/0/6 changed to down.

行 5863: %@225217%Sep  6 02:00:50:978 2026 CORE-Video IFNET/5/LINK_UPDOWN: Line protocol state on the interface GigabitEthernet2/1/0/6 changed to down.

行 5866: %@225220%Sep  6 02:00:51:070 2026 CORE-Video IFNET/3/PHY_UPDOWN: Physical state on the interface GigabitEthernet1/1/0/5 changed to down.

行 5868: %@225222%Sep  6 02:00:51:089 2026 CORE-Video IFNET/5/LINK_UPDOWN: Line protocol state on the interface GigabitEthernet1/1/0/5 changed to down.

行 5872: %@225226%Sep  6 02:00:52:971 2026 CORE-Video IFNET/3/PHY_UPDOWN: Physical state on the interface GigabitEthernet1/1/0/5 changed to up.

行 5873: %@225227%Sep  6 02:00:52:981 2026 CORE-Video IFNET/5/LINK_UPDOWN: Line protocol state on the interface GigabitEthernet1/1/0/5 changed to up.

行 5877: %@225231%Sep  6 02:00:53:172 2026 CORE-Video IFNET/3/PHY_UPDOWN: Physical state on the interface GigabitEthernet2/1/0/6 changed to up.

行 5878: %@225232%Sep  6 02:00:53:175 2026 CORE-Video IFNET/5/LINK_UPDOWN: Line protocol state on the interface GigabitEthernet2/1/0/6 changed to up.

行 5882: %@225236%Sep  6 02:00:55:315 2026 CORE-Video IFNET/3/PHY_UPDOWN: Physical state on the interface GigabitEthernet2/1/0/6 changed to down.

行 5886: %@225240%Sep  6 02:00:55:354 2026 CORE-Video IFNET/5/LINK_UPDOWN: Line protocol state on the interface GigabitEthernet2/1/0/6 changed to down.

行 5887: %@225241%Sep  6 02:00:55:418 2026 CORE-Video IFNET/3/PHY_UPDOWN: Physical state on the interface GigabitEthernet1/1/0/5 changed to down.

行 5889: %@225243%Sep  6 02:00:55:439 2026 CORE-Video IFNET/5/LINK_UPDOWN: Line protocol state on the interface GigabitEthernet1/1/0/5 changed to down.

行 5894: %@225248%Sep  6 02:00:57:247 2026 CORE-Video IFNET/3/PHY_UPDOWN: Physical state on the interface GigabitEthernet2/1/0/6 changed to up.

行 5895: %@225249%Sep  6 02:00:57:258 2026 CORE-Video IFNET/5/LINK_UPDOWN: Line protocol state on the interface GigabitEthernet2/1/0/6 changed to up.

行 5898: %@225252%Sep  6 02:00:57:320 2026 CORE-Video IFNET/3/PHY_UPDOWN: Physical state on the interface GigabitEthernet1/1/0/5 changed to up.

行 5899: %@225253%Sep  6 02:00:57:331 2026 CORE-Video IFNET/5/LINK_UPDOWN: Line protocol state on the interface GigabitEthernet1/1/0/5 changed to up.

行 5900: %@225254%Sep  6 02:00:59:984 2026 CORE-Video IFNET/3/PHY_UPDOWN: Physical state on the interface GigabitEthernet2/1/0/6 changed to down.

行 5904: %@225258%Sep  6 02:01:00:021 2026 CORE-Video IFNET/5/LINK_UPDOWN: Line protocol state on the interface GigabitEthernet2/1/0/6 changed to down.

行 5905: %@225259%Sep  6 02:01:00:065 2026 CORE-Video IFNET/3/PHY_UPDOWN: Physical state on the interface GigabitEthernet1/1/0/5 changed to down.

行 5908: %@225262%Sep  6 02:01:00:100 2026 CORE-Video IFNET/5/LINK_UPDOWN: Line protocol state on the interface GigabitEthernet1/1/0/5 changed to down.

 

过程分析

根据port mapping信息找到对应接口的link-diag诊断日志:

====display hardware internal port link-diag chassis 1 slot 1 4====  

==============================================================================

 Chassis 1 Slot 1/port/tgid:4 operation record, need be translated with code and line num

=============================================================================

 

 [0]:PID=679 TName=LinkS Line=2842  09/06/2026 02:02:11:718

     m0=0 m1=0 m2=1   drv_port_LinkChangeToPlatform

 [1]:PID=679 TName=LinkS Line=2847  09/06/2026 02:02:08:935

     m0=0 m1=0 m2=1   drv_port_LinkChangeToPlatform

 [2]:PID=679 TName=LinkS Line=2842  09/06/2026 02:02:04:612

     m0=0 m1=0 m2=1   drv_port_LinkChangeToPlatform

 [3]:PID=679 TName=LinkS Line=2847  09/06/2026 02:02:01:518

     m0=0 m1=0 m2=1   drv_port_LinkChangeToPlatform

 [4]:PID=679 TName=LinkS Line=2842  09/06/2026 02:01:17:995

     m0=0 m1=0 m2=1   drv_port_LinkChangeToPlatform

 [5]:PID=679 TName=LinkS Line=12212  09/06/2026 02:01:17:684

     m0=1000 m1=0 m2=2   drv_port_SetCtcSpeed

 [6]:PID=679 TName=LinkS Line=2847  09/06/2026 02:01:14:901

     m0=0 m1=0 m2=1   drv_port_LinkChangeToPlatform

 [7]:PID=679 TName=LinkS Line=2842  09/06/2026 02:01:02:856

     m0=0 m1=0 m2=1   drv_port_LinkChangeToPlatform

 [8]:PID=679 TName=LinkS Line=12212  09/06/2026 02:01:02:545

     m0=100 m1=1 m2=2   drv_port_SetCtcSpeed

 [9]:PID=679 TName=LinkS Line=2847  09/06/2026 02:01:00:068

     m0=0 m1=0 m2=1   drv_port_LinkChangeToPlatform

 [10]:PID=679 TName=LinkS Line=2842  09/06/2026 02:00:57:281

     m0=0 m1=0 m2=1   drv_port_LinkChangeToPlatform

 [11]:PID=679 TName=LinkS Line=2847  09/06/2026 02:00:55:419

     m0=0 m1=0 m2=1   drv_port_LinkChangeToPlatform

 [12]:PID=679 TName=LinkS Line=2842  09/06/2026 02:00:52:948

     m0=0 m1=0 m2=1   drv_port_LinkChangeToPlatform

 [13]:PID=679 TName=LinkS Line=12212  09/06/2026 02:00:52:636

     m0=10 m1=2 m2=2   drv_port_SetCtcSpeed

 [14]:PID=679 TName=LinkS Line=2847  09/06/2026 02:00:51:075

     m0=0 m1=0 m2=1   drv_port_LinkChangeToPlatform

发现接口速率在10-1000之间变化,怀疑是速率自协商的问题。查看交换机故障处理手册,发现对于电口反复UP/DOWN的情况,有可能是由于自协商情况下容易出现协商不稳定,这种情况可以尝试设置强制速率双工。

解决方法

本端与对端接口都配置强制速率双工(speed 1000/duplex full),可以消除速率自协商情况下的不稳定情况。

该案例对您是否有帮助:

您的评价:1

若您有关于案例的建议,请反馈:

0 个评论

该案例暂时没有网友评论

编辑评论

举报

×

侵犯我的权益 >
对根叔知了社区有害的内容 >
辱骂、歧视、挑衅等(不友善)

侵犯我的权益

×

泄露了我的隐私 >
侵犯了我企业的权益 >
抄袭了我的内容 >
诽谤我 >
辱骂、歧视、挑衅等(不友善)
骚扰我

泄露了我的隐私

×

您好,当您发现根叔知了上有泄漏您隐私的内容时,您可以向根叔知了进行举报。 请您把以下内容通过邮件发送到pub.zhiliao@h3c.com 邮箱,我们会尽快处理。
  • 1. 您认为哪些内容泄露了您的隐私?(请在邮件中列出您举报的内容、链接地址,并给出简短的说明)
  • 2. 您是谁?(身份证明材料,可以是身份证或护照等证件)

侵犯了我企业的权益

×

您好,当您发现根叔知了上有关于您企业的造谣与诽谤、商业侵权等内容时,您可以向根叔知了进行举报。 请您把以下内容通过邮件发送到 pub.zhiliao@h3c.com 邮箱,我们会在审核后尽快给您答复。
  • 1. 您举报的内容是什么?(请在邮件中列出您举报的内容和链接地址)
  • 2. 您是谁?(身份证明材料,可以是身份证或护照等证件)
  • 3. 是哪家企业?(营业执照,单位登记证明等证件)
  • 4. 您与该企业的关系是?(您是企业法人或被授权人,需提供企业委托授权书)
我们认为知名企业应该坦然接受公众讨论,对于答案中不准确的部分,我们欢迎您以正式或非正式身份在根叔知了上进行澄清。

抄袭了我的内容

×

原文链接或出处

诽谤我

×

您好,当您发现根叔知了上有诽谤您的内容时,您可以向根叔知了进行举报。 请您把以下内容通过邮件发送到pub.zhiliao@h3c.com 邮箱,我们会尽快处理。
  • 1. 您举报的内容以及侵犯了您什么权益?(请在邮件中列出您举报的内容、链接地址,并给出简短的说明)
  • 2. 您是谁?(身份证明材料,可以是身份证或护照等证件)
我们认为知名企业应该坦然接受公众讨论,对于答案中不准确的部分,我们欢迎您以正式或非正式身份在根叔知了上进行澄清。

对根叔知了社区有害的内容

×

垃圾广告信息
色情、暴力、血腥等违反法律法规的内容
政治敏感
不规范转载 >
辱骂、歧视、挑衅等(不友善)
骚扰我
诱导投票

不规范转载

×

举报说明

提出建议

    +

亲~登录后才可以操作哦!

确定

亲~检测到您登陆的账号未在http://hclhub.h3c.com进行注册

注册后可访问此模块

跳转hclhub

你的邮箱还未认证,请认证邮箱或绑定手机后进行当前操作